Opening Up a 1980s Builder Home in Dallas

1980s Home Guide Opening Up a 1980s Builder Home in Dallas Short Answer Can you open up a 1980s builder home? Usually, yes, and often with fewer surprises than in a 1950s house. Many homes built from the 1980s onward use factory built roof trusses that span from exterior wall to exterior wall, so a lot of interior walls are plain partitions. But “many” is not “all.” Trusses can land on an interior wall at a girder truss or other special support, two story homes carry the second floor on walls below, and some 1980s houses are stick framed with a center bearing line. The only safe approach is to confirm each wall before anyone cuts it. This guide covers what 1980s builder homes in Dallas and DFW tend to have behind the drywall, which walls to check first, what else can turn up during demolition, and how the process runs. Planning to open a kitchen, dining or living room wall? Call 972-640-6090 or request a free estimate. Roof Framing Why 1980s homes are a different case Older houses (the 1920s through the 1960s) were mostly stick framed on site, with ceiling joists and rafters that rest on interior bearing walls. Homes from the 1980s on are more likely to use trusses, which are engineered frames built in a factory. Truss roofs and interior walls. Most houses with roof trusses do not have interior bearing walls, while stick framed houses often have a center bearing wall. That is a useful starting point, not a conclusion. The catch. Trusses can create concentrated bearing points. Girder trusses and other special supports can sit on an interior wall, and a common mistake is assuming every interior wall is non bearing, then discovering a girder or bearing point after the cut. Two story homes are different again. On the main floor of a two story house, an interior wall may carry the second floor joists, the walls above them and, through those walls, part of the roof. So a 1980s home sits in the middle. The odds of a removable wall are better than in an older house, and the cost of guessing wrong is the same. Which Walls Which walls are most likely to be structural Wall What to know Exterior walls Nearly all exterior walls in wood framed homes are load bearing. They support the roof trusses or rafters and perimeter floor framing First floor walls under a second floor A wall that sits directly under another wall above is the classic load path Walls running down the middle of the house Often support joists or trusses, especially in stick framed roofs Walls perpendicular to the joists above If the joists land on the wall, it is likely load bearing. Parallel walls are often non bearing, but not always Walls near a stair opening or long span Girder trusses and extra framing often sit near these Short partitions that look “special” Multi ply framing or unusual web layouts at the attic side can mark a bearing point Kitchen and bath dividing walls with soffits above Look at what the soffit is hiding before assuming it is only trim A reminder that applies to every house: joist direction is only one clue. Wall thickness, stud count and rules of thumb help, but they are not proof. Original permit drawings, when the city still has them, can show beams, posts and roof framing direction. Availability varies by city. For the basics, see how to tell if a wall is load bearing in Dallas and warning signs of a load bearing wall problem. Attic Check What to look for in the attic If the attic is accessible, a safe look from the walkway can answer a lot: Trusses or rafters? Triangulated frames with angled webs and metal gusset plates point to trusses. Individual rafters and ceiling joists point to stick framing. Where do they land? Note whether trusses are resting on the exterior walls only, or also on an interior wall. Anything unusual? Doubled or tripled trusses, extra blocking or posts, or an unusual web layout can mark a girder truss or special support. Cut or modified framing. Trusses that have been cut or altered by earlier work are a red flag. Chords and webs are structural, and cutting them is a serious problem. Storage and equipment. Heavy storage or an air handler above the wall changes the load. Take photos and measurements. They help an engineer far more than a description. One caution: even a house with engineered trusses can end up with a bearing wall after an addition, a past remodel or a roof reframe. The roof you see may not be the roof the house was built with. Common Features Common features of 1980s builder homes, and what they mean for wall removal Closed, compartmentalized layouts Many builder homes of the era are laid out as separate formal rooms with a wall or pass through between kitchen and family areas. That is the reason opening them up is such a popular project. See open concept kitchen ideas with wall removal and combining a kitchen and living room. Soffits and bulkheads Drop soffits above kitchen cabinets and over hallways are common. Some are just empty boxes. Others hide ductwork, plumbing, wiring or framing. Taking one out can change how a ceiling meets a new beam, so it should be opened up and checked during planning, not in the middle of demolition. Brick veneer, block and slab Many DFW homes of this period have brick veneer over wood framing, and many sit on a concrete slab. A wall on a slab that becomes a beam support needs a post that lands on something able to carry it. A post set on a plain slab edge is a common mistake. Posts and columns usually need proper footings under the slab, which means cutting and pouring concrete. Plan for that in schedule and budget. For soil related issues, see clay soil and renovation in Dallas.

General Blog
Repairing a Sagging Beam in Dallas Homes

Beam Repair Guide Repairing a Sagging Beam in Dallas Homes Short Answer How do you repair a sagging beam? A sagging beam is repaired by finding out why it sagged, supporting the load, slowly lifting the beam where that is safe, and then adding permanent support. That support is usually a new post or column at the lowest point, a sister beam or steel reinforcement bolted alongside, or full replacement with an engineered beam. Which one applies depends on the cause (overload, undersized beam, rot, termites, a failed post or footing, or a removed wall), and the choice should come from a structural engineer, not from a guess. Fixing only the sag without fixing the cause is the most common reason a repair fails. A beam that sank because its post settled will sag again if the post is left alone. Beam sagging after a remodel, or getting worse over time? Call 972-640-6090 or request a free estimate. Deflection First, is it really sagging too much? Every beam bends a little under load. Engineers set limits on that bending, called deflection, so floors do not feel bouncy and finishes do not crack. Common design limits are expressed as a fraction of the span, written as L over a number. Two numbers come up often in these discussions: L/360, commonly used for floors and for live load deflection. Deflection measured against that limit is the standard way to tell whether a floor or beam is past what is acceptable. L/240, often cited for total load on other members. As a worked example, a 16 foot span is 192 inches. L/360 works out to about half an inch (192 divided by 360), and L/240 works out to about eight tenths of an inch. A beam that has visibly dropped more than that over its span deserves a closer look. Treat these as reference points only. The right limit for a particular beam depends on what it carries and what is attached to it, and an engineer sets that. One more thing to watch: progressive sag. A sag that is getting measurably worse over months points to active movement and should be looked at no matter how small it is today. Causes Why beams sag Cause What it looks like Undersized from the start Gentle, long sag over the full span, often in older or DIY framing Overloaded by a change Sag that began after a remodel, a new roof layer, added floors, or heavy new loads Wall removed, beam undersized Sag soon after a wall came out. The new beam may carry more than it was sized for Rot or moisture Soft wood, staining, damaged bearing ends or beam pockets Termites Hollow sounding wood, mud tubes, frass Post or footing failure Sag concentrated near one support, with the post sunk, tilted or rotted at the base Joints and splices opening Nail holes elongated, butt joints opened up, a built up beam coming apart Creep over time Slow, permanent sag in wood under constant long term load Foundation movement Sag along with diagonal cracks, sticking doors and gaps at walls One engineering case shows how a hidden cause can sit behind a simple sag. A homeowner reported a two inch ceiling sag after a remodel. The engineer found that the beam had replaced what used to be a load bearing wall, that a new roof had been built over the old one so more load was landing on it, and that no foundation supported the beam below. The fix involved a 25 foot steel beam, columns and a new foundation system, and the repair cost more than $12,000 in that case. That figure belongs to that one project and is not a Dallas price, but it shows why the cause has to be found before anything is bolted on. For the related symptoms, see what causes a sagging ceiling and sagging floors in older Dallas homes. Step One Step one: stop adding load and get the cause diagnosed Before any repair, the following should be known: Where the sag is greatest, and how much it has moved (measure from a string line or a straight edge, and note the date). What the beam carries: floor joists, a wall above, roof framing, a point load. What it bears on: posts, walls, beam pockets, footings. The condition of the wood: rot, termites, checking, splits, failed splices. Whether a past remodel changed the load path. If the beam, its posts or its footings are cracked, split, rotted or sinking, avoid placing heavy furniture or appliances on the span and avoid adding any new load until a licensed structural engineer has evaluated it. Sistering or reinforcing a beam does not cure a sag caused by a sinking post or rotted bearing end. The support under it has to be fixed first. An engineer can also tell whether the problem is the beam at all. A sagging floor can come from joists, a girder, rotted bearing pockets or foundation movement, and each has a different repair. For more on that step, see hiring a structural engineer for load bearing wall removal in Dallas. Repair Options Repair options for a sagging beam Option How it works Best suited to Limits Add a post or column at the sag The beam is jacked up and a new post or column is installed where the sag is greatest, which shortens the span and reduces the load on the weak beam Basements and crawlspaces where a post can sit on a proper footing Hard to add in a finished living area. The post needs a footing that can carry the load Sister beam (wood or engineered lumber) A new beam of the same size, or an LVL, is fastened alongside the old one, usually after the old one is jacked back toward position Beams that are structurally sound but undersized Full length bearing and proper fastening matter. A partial length sister may do little Steel flitch plate A steel plate is

Does Foundation Movement Affect Load-Bearing Walls? What Dallas Homeowners Should Know
General Blog
What Causes a Sagging Ceiling in Dallas Homes?

Ceiling Guide What Causes a Sagging Ceiling in Dallas Homes? Short Answer What causes a sagging ceiling? A sagging ceiling usually comes from one of two places. Either the ceiling covering has failed (wet or overloaded drywall, loose fasteners, drywall that is too thin for the span), or the framing above it has moved (undersized or cut joists, a removed wall, termite or rot damage, or foundation movement). The covering problems are common and often fixable without touching the structure. The framing problems are the ones that cannot wait, and the two can look almost the same from the floor. The fastest way to tell them apart is to look at when the sag appeared, how wide it is, and whether anything wet or recently remodeled sits above it. This guide walks through each cause, how to sort one from another, and when a structural check is the right call. Ceiling dropped after a wall came out, or the sag is spreading? Call 972-640-6090 or request a free estimate. Quick Comparison Two kinds of sagging ceilings   Surface problem Structural problem What is failing Drywall, plaster, fasteners, insulation load Joists, beams, bearing walls, supports Typical shape Soft bulge or pillow between joists, a dropped seam A long, shallow dip across a room, or a line that follows a former wall Common companions Stains, peeling paint, popped screws, cracked tape Cracked drywall at corners, sticking doors, a bouncy or sloped floor above Typical timing After a leak, after added insulation, over many years Soon after a remodel, or slowly worsening over time Who fixes it Drywall or restoration contractor, after the cause is stopped Structural engineer first, then a framing contractor One thing to keep in mind: a ceiling that looks like a surface problem can still be hiding a framing problem. A leak that soaked drywall may also have soaked the joists above it. Common Causes The most common causes, one by one 1. Water above the ceiling Water damage is the most frequent reason a ceiling drops. Sources include roof leaks, a failed plumbing line or fixture in the room above, and attic equipment. In DFW, many homes have the air handler in the attic, so a clogged condensate line or an overflowing drain pan can quietly soak the ceiling below. Why water makes drywall sag: gypsum board depends on a crystalline core and paper faces, and liquid water weakens both. Drywall on a ceiling is under constant load from gravity, so once it is weakened it keeps creeping downward. Wet insulation adds weight on top of that. What to look for: Brown or yellow stains, even faint ones Peeling paint, bubbles or a musty smell A sag that feels soft or looks swollen The rule here is simple. Stop the source first, then repair. Patching a ceiling before the leak is fixed is wasted money. 2. Heavy or wet attic insulation Insulation adds load to the drywall under it. Dry insulation on properly fastened drywall is normally fine. The trouble starts when drywall is old, thin or already weak, when more insulation gets added over the years, or when a roof leak soaks the insulation. Wet blown in insulation gets heavier, and the water also weakens the drywall that has to carry it. A sag that spreads over a wide area, with no fresh stain, often points here. It tends to look worse after insulation was added in the attic. 3. Drywall that is too thin for the span Half inch drywall hung under roof trusses spaced 24 inches apart can sag between the framing members, sometimes called pillowing. Thicker five eighths inch board resists sag better over that span, and the weight of attic insulation makes a thin board worse. If the sag appears as soft, shallow bulges between framing lines on a top floor ceiling, with no stains, this is a likely suspect. 4. Loose fasteners and failed joints Screws and nails can back out or pull through the paper over time. Once the board stops being held to the framing, it drops. The signs are popped fasteners, a taped seam that has opened, or a localized belly around one joint. A string line across the attic side will usually show the joists themselves are still straight. 5. A wall was removed and the ceiling framing lost its support This is the cause that matters most for homeowners planning remodels. In many houses, a wall carries the ends of ceiling joists, or supports the load above them. When it comes out without the right beam, the ceiling can drop. A structural engineer commenting on one remodel case explained why: ceiling joists that once spanned to an unyielding bearing wall are now supported by something far more flexible, with connections far from where the load lands. Another case described a wall that was assumed to be non load bearing, replaced with a small beam that only picked up the ceiling framing. Over time the beam deflected, and the ceiling sagged. In a third example, an engineer measured two inches of deflection on a beam that had replaced a load bearing wall. A rough guide for timing: a ceiling that drops a half inch soon after a wall removal is a concern. One that drops an inch or two is a bigger concern that the load was not properly supported. Either one calls for a structural engineer, not a cosmetic patch. If this matches what happened in your home, read the warning signs of a load bearing wall problem and what a structural engineer checks before wall removal. 6. Undersized, overspanned or cut joists Ceiling joists are sized for a span and a load. Problems come from joists that were too small from the start, which is more common in older homes built before modern engineering standards, and from joists that were notched or cut to make room for ducts, pipes or wiring. Heavy storage in the attic adds load too. A homeowner can often check for

General Blog
Termite or Water Damage to Beams in Dallas Homes

Beam Damage Guide Termite or Water Damage to Beams in Dallas, TX: Signs, Repairs and When to Call an Engineer A beam can look perfectly normal and still be mostly hollow. That is the unsettling thing about termites and wood rot. They work from the inside, or in places you never look, and the first clue is often a floor that has started to sag or a door that has started to stick. Beams are the part of the house that collects and carries the load from floors and walls above. When one is damaged, the house does not just have a cosmetic problem. It has a structural one. And it is a problem that often turns up in the middle of another project, such as a wall removal, when the wall is opened and the old beam is finally visible. This guide explains how termites and moisture damage beams, how to spot it, how repair differs from replacement, why the cause has to be fixed first, and who should be involved. It is written for Dallas and DFW homeowners, especially those with pier and beam foundations or older homes. Short Answer What Should You Do About a Termite or Water Damaged Beam? Get it inspected before you do anything else. Probing the wood, checking for moisture and finding the source of the damage tells you whether the beam can be repaired or has to be replaced. Fix the cause, not just the wood. Termites need to be treated and moisture needs to be stopped, or new lumber will face the same fate. Repair or replace depends on how much good wood is left. A structural engineer measures what remains and decides whether sistering, reinforcement or full replacement is right. Temporary support comes first. A damaged beam is still carrying load, so it is supported before any work starts. Suspect a problem with a beam in your house? We can take a look and bring in the engineer. Call 972-640-6090 or request a free estimate. How It Happens How Termites and Moisture Damage Beams Termites. Subterranean termites nest in the soil and use mud tubes to reach wood, according to This Old House, and they are found in every US state except Alaska. They tunnel inside wood, generally following the grain, so a beam can look normal on the outside while the inside is hollowed out. Water and rot. Wood rot is a fungus problem, and rot needs four things: moisture, food, oxygen and a suitable temperature. One experienced builder on a Fine Homebuilding forum points out that moisture is the one you can realistically remove, since you cannot take away the lumber, the oxygen or the temperature. Sources of moisture include poor grading, downspouts discharging next to the foundation, plumbing leaks, roof leaks and humid air in a crawl space. They work together. Damp wood attracts pests, and pests open wood to more moisture. Moisture is the most common thread in crawl space structural damage, according to one inspection guide. Why DFW homes matter. Older pier and beam homes in Texas often have wood joists and beams close to the soil in a crawl space, which is a more exposed setup than a slab. A pest control company in central Texas notes that many older pier and beam homes have untreated wood in crawl spaces, making them especially vulnerable to attack from the soil below. See older Dallas homes with pier and beam foundations. On a slab, damage tends to show up where plumbing leaks, around roof or window leaks, or in the garage and attic. Warning Signs Signs a Beam May Be Damaged On the beam itself: Wood that sounds hollow or dull when you tap it with a screwdriver handle. Texas A&M AgriLife Extension advises examining wood that sounds dull or hollow when struck, then checking suspected areas with a sharp pointed tool such as an ice pick to find termites or their damage. Soft wood that a screwdriver sinks into easily. Crumbling, powdery or cracked wood, and a musty smell. Dark staining or white fungal growth. Sunken lines or blisters in paint or finishes. Around it: Mud tubes on foundation walls, piers or sill plates. Pencil thick tubes are the most recognizable sign of subterranean termites. Drywood termites do not make mud tubes, so no tubes does not prove there are no termites. Swarmers or discarded wings near windows and doors. Termite damage can look like water damage. This Old House notes that subterranean termites can cause issues, such as blisters in flooring or wall coverings, that look a lot like water damage. In the house: Sagging or bouncy floors, or floors that slope. Doors and windows that stick, or cracks in drywall. Gaps where a beam meets a wall or post. See sagging floors in older Dallas homes, cracked drywall vs. structural damage and warning signs of a load bearing wall problem. Many of these signs also come from foundation movement, which is common with Dallas clay soil, so diagnosis matters. See foundation movement and load bearing walls. Where to Look Where Beam Damage Hides Beam ends in foundation pockets. One forum example describes termite damage on a beam extending about 3.5 feet from the foundation pocket. Beam bottoms and ends where they sit on piers or posts, where moisture collects. Near plumbing penetrations and drains. Crawl space beams close to soil. Attic beams and headers below roof leaks. Hidden beams above ceilings or inside walls, which show up during remodels. Remember that a beam you cannot see cannot be checked. That is why inspections happen when a wall or ceiling is opened. See hidden costs of wall removal. What to Do First The Right Order of Operations 1 Do not load the beam further. Do not add weight, and do not remove supports. 2 Inspect it. A pest control inspection finds termites and a structural inspection checks the beam. Take photos and note moisture readings. 3 Find and stop the source. That means

General Blog
Can Your Home Support a Large Glass Wall?

Glass Wall Guide Can Your Home Support a Large Glass Wall? What Dallas Homeowners Need to Know A wall of glass is the dream version of a patio door. Instead of a slider and a window, you get a whole side of the room that opens to the backyard, with a view that changes the way the house feels. It is also the biggest opening most homeowners will ever cut into an exterior wall. The glass is heavy, the opening is wide, and the wall it replaces was probably holding up part of your roof. So the real question is not whether you can buy a glass wall. It is whether your house can carry one. This guide walks through what a large glass wall asks of your home: the header, the posts, the bracing, the foundation, the floor, the air conditioning and the permit. It is written for Dallas and DFW homeowners who want to know what is realistic before they fall in love with a brochure. Short Answer Can a House Support a Large Glass Wall? Often yes, but not without engineering. Most homes can be modified to take a wide glass opening. It takes a properly sized beam, solid supports below, and a check of the roof framing, the wall bracing and the foundation. The header does most of the work. A hole large enough for a double door can bring the house down if the header is wrong. And even a header that is strong enough can sag enough to jam the doors. The slab and the floor matter more than people expect. Big glass systems need a level, stable base. In North Texas, with clay soil that moves, that deserves attention. Your air conditioner will notice. A wall of glass changes the heat load, especially facing south or west. Thinking about a big opening? We can look at your wall and bring in the engineer before you pick a door system. Call 972-640-6090 or request a free estimate. What Types What Counts as a Large Glass Wall? System How it works What it asks of the house Large slider or double door Two or three panels, a normal patio door scaled up Wider header, stronger jack studs Multi slide door Several panels stacked on parallel tracks at one or both ends A stacking area beside the opening Pocket system Panels slide fully into a cavity built in the wall A deep, weather protected pocket, the most structural change Folding (bifold) glass wall Panels fold and stack Careful header deflection and track alignment Fixed glass wall Large panes that do not open A strong frame, lots of glass weight EngineerFix describes the multi slide family as panels that operate independently on parallel tracks and stack neatly at the ends, and the pocket version as ultimately unobstructed, but requiring substantial structural modification and wall space. A word on size. A contractor interviewed by Journal of Light Construction said it is unlikely that someone would put an 8 foot or 24 foot wide system into a retrofit, and that long span glazing is more appropriate for an addition or a new home. Retrofits are possible, but a bigger opening in an existing house costs and complicates more than the same opening in new construction. Check 1 Check 1: The Header and What It Carries The header is the beam over the opening, and the bigger the opening, the more it matters. If you want the basics, read what a header is. A Journal of Light Construction engineering column puts it bluntly: for a small window you can select a header from experience, but a hole large enough for a double door can bring the house down. The same article points out that a header under load sags, and if the door frame is attached to the header, the frame sags with it and the door jams. Strong is not enough. A sliding door runs on a track, and a lift and slide system has tight tolerances. One Journal of Light Construction article tells a story where the engineer said a beam met standard specs, and the project manager pointed out it was not a regular patio door but a lift and slide with tight tolerances. The beam has to be stiff, not only strong, and the door manufacturer’s deflection limit goes to the engineer before the beam is chosen. What sits on the header. The roof matters. A journal article warns that if the roof is framed with rafters and a structural ridge beam, the post that supports the ridge may be interrupted by the opening, and that needs an engineer to resolve. If your roof uses trusses, the load is delivered differently, and the engineer needs to know which you have. Typical solutions. Contractors quoted in the trade press say a steel beam header running across the home is common for large openings, and others use LVL, glulam or flitch beams. See steel beam vs. flitch beam and LVL vs. steel beam costs. The minimum is a minimum. The code sets minimum header and jack stud sizes for conventional configurations, and one remodeler notes the key word is minimum, because you can always overbuild. For a big glass wall, the engineer designs for the opening, not from a table. Check 2 Check 2: Posts, Bracing and Wind A wide opening removes wall. The solid sections left on each side have to carry the header load down and also keep the wall stiff against wind. Posts under the header ends need support all the way down. See what is under the posts for why footings matter. Braced wall panels. The International Residential Code requires braced wall panels at corners and at regular intervals. Narrow wall sections beside a big opening may be too flexible for conventional bracing, and special methods or engineered panels may be needed. Roof and ceiling tie in. The engineer checks how the roof framing meets the wall. A homeowner on Houzz describes learning